Accuracy
- ± (0.10° C (0.18° F) + 0.10 % of Calibrated Span) with Two-Point Calibration
Cable Length
- Extension Cable: 6.5 to 16.4 feet (2 to 5 metres)
Materials of Construction
- Armor over Teflon Cable & Ferrule: Stainless Steel
- Ferrule: Brass
- Ferrule: Teflon
NPT Connection
- 1” NPT Male
- 1/2” NPT Male
- 1/4” NPT Male
- 1/8” NPT Male
- 3/4” NPT Male
- 3/8” NPT Male
Operating Temperature
- -50° to 200° C (-58° to 392° F)
Output
- 0-10 Vdc, 3-Wire, Linear to Temperature
- 0-5 Vdc, 3-Wire, Linear to Temperature
- 1-5 Vdc, 3-Wire, Linear to Temperature
- 4-20 mA Loop Powered, 2-Wire, Linear to Temperature
Power Supply
- 10-32 Vdc 2-Wire Loop Power
Process Connection Material
Sensor, Probe Diameter
- 1/8 to 1/2” (3.17 to 12.7 mm)
Sensor, Probe Material
- 316 Stainless Steel
- 316L Stainless Steel
Temperature Range
- Sensor: -200° to 600° C (-328° to 1,112° F)