Accuracy
- ± (0.10° C (0.18° F) + 0.10 % of Calibrated Span) with Two-Point Calibration
- ± (0.25° C (0.45° F) + 0.40 % of Span) with One-Point Calibration
Diameter
- Pad: 1/2” (12.7 mm)
- Pad: 3/8” (9.5 mm)
Environmental Protection
- IP67 Hermetically Sealed
- NEMA 6P Hermetically Sealed
Input Impedance
- 1,000 ohms Min. (of Measuring Device, for Voltage Output)
Lead Insulation
- Fiberglass with Stainless Steel Armor & Overbraid
- PVC
- Teflon with Stainless Steel Armor & Overbraid
Materials of Construction
- Pad Material: 316 Stainless Steel
- Pad Material: Aluminum
- Pad Material: Bass
Operating Pressure
- Sensor psig: 500 (kPa: 3,447, bar: 34.47)
Operating Temperature
- Housing: -40° to 80° C (-40° to 175° F)
Output
- 0-10 Vdc Linear to Temperature
- 0-5 Vdc Linear to Temperature
- 1-5 Vdc Linear to Temperature
- 4-20 mA Loop Powered, Linear to Temperature
Power Supply
- 12-32 Vdc Polarity Protected
Sensor Circuit
- 2.5 mA Downscale for 4-20 mA Output
- 24 mA Upscale for 4-20 mA Output
Stability
- Long Term Drift: ≤ 0.1 % of Full Scale Per Year
Storage Temperature
- -40° to 80° C (-40° to 176° F)
Temperature Range
- -50° to 400° C (-58° to 752° F)
Wetted Materials
- 316 Stainless Steel, Dual Certified
- 316L Stainless Steel, Dual Certified