R22 Direct Immersion RTD

Brand: Intempco Controls, Inc

Specifications
  • Ideal for quick disconnect applications
  • Standard RTD connectors available
  • Adjustable or fittings welded to probe available
  • Many fitting sizes and probe diameters available
  • RTD Pt100 ohm standard, others available
  • 2, 3 or 4-Wire circuit types
  • Isolation to 1,000 Vdc
  • Factory calibration certificate optional
  • Custom designs available

Specifications

Insertion 'U' Length

  • 1 to 48” (25.4 to 1,219 mm)

Materials of Construction

  • Ferrule Material & Lead Wire Insulation (FEP, TFE): Teflon
  • Ferrule Material: Brass
  • Ferrule Material: Stainless Steel
  • Lead Wire Insulation (Overall Jacket): Aluminum
  • Lead Wire Insulation (Overall Jacket): Mylar
  • Lead Wire Insulation: Glass
  • Lead Wire Insulation: Kapton

NPT Connection

  • 1/2” NPT Male
  • 1/4” NPT Male
  • 1/8” NPT Male
  • 3/4” NPT Male
  • 3/8” NPT Male

Process Connection Material

  • Brass
  • Stainless Steel

RTD Type

  • Pt100 ohm at 0° C (32° F), α = 0.00385 DIN EN 60751
  • Pt1000 ohm at 0° C (32° F), α = 0.00385 DIN EN 60751

Sensor, Probe Connection

  • 2-Wire (Single/Dual)
  • 3-Wire (Single/Dual)
  • 4-Wire (Single)

Sensor, Probe Diameter

  • Probe: 1/16 to 1/2” (1.6 to 12.7 mm)

Sensor, Probe Material

  • Probe: 316 Stainless Steel
  • Probe: 316L Stainless Steel
  • Probe: Inconel 600

Temperature Range

  • -200° to 600° C (-328° to 1,112° F)
  • Lead Wire Insulation: 200° to 482° C (392° to 900° F)

Tolerance

  • Element: ± 0.04 % (± 0.1° C) at 0° C (32° F), Class AA
  • Element: ± 0.06 % (± 0.15° C) at 0° C (32° F), Class A
  • Element: ± 0.12 % (± 0.3° C) at 0° C (32° F), Class B

show more